Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
3.
JACC Case Rep ; 29(3): 102191, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361557

RESUMO

An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed.

4.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

5.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
7.
Am J Cardiol ; 210: 146-152, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37838072

RESUMO

Limited data are available about the impact of permanent pacemaker (PPM) implantation on long-term survival in patients with a bicuspid aortic valve (BAV) and severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR). We aimed to evaluate the long-term clinical outcomes of patients with BAV with AS who underwent periprocedural PPM implantation after TAVR with a self-expandable prosthesis. Data from patients with BAV and severe AS who underwent TAVR between April 2009 and January 2022 and followed in the framework of the One Hospital ClinicalService-CoreValve Project were collected. Patients were categorized in 2 groups according to PPM implantation after TAVR ("PPM" group) or not ("no PPM" group). The coprimary end points were all-cause death and a composite of cardiac mortality, rehospitalization because of cardiac causes, stroke, and myocardial infarction. Overall, 106 patients were considered (74 in the "no PPM" group and 32 in the "PPM" group). No statistically significant difference was found between the groups in terms of follow-up and baseline characteristics. Patients in the PPM group were more likely to show baseline conduction abnormalities (p = 0.023). Patients in the PPM group were more often treated with older generation prosthesis than those in the no PPM group (28.1% vs 5.4%, respectively, p = 0.013). At 2 years of follow-up, all-cause death in the no PPM and PPM groups occurred in 20.0% and 10.0% of patients, respectively (hazard ratio 0.37, 95% confidence interval 0.08 to 1.67). Similarly, no difference was evident for the composite end point between the 2 groups (no PPM vs PPM: 8 [14.6%] vs 6 [19.3%], hazard ratio 1.67, 95% CI 0.58 to 4.81). In conclusion, patients with severe AS and BAV treated with TAVR complicated by PPM implantation are not exposed to an increased risk of major adverse events at 2 years of follow-up.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Válvula Aórtica Bicúspide/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
8.
Artigo em Inglês | MEDLINE | ID: mdl-37931791

RESUMO

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

9.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37933728

RESUMO

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Angiografia Coronária/métodos
10.
Circ Cardiovasc Interv ; 16(12): e013232, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37874646

RESUMO

BACKGROUND: Drug-coated balloons (DCB) are an emerging tool for modern percutaneous coronary intervention (PCI), but evidence on their use for de novo lesions on large vessels is limited. METHODS: Consecutive patients undergoing DCB-based PCI on the left anterior descending artery in 2 Italian centers from 2018 to 2022 were retrospectively enrolled and compared with patients who received left anterior descending PCI with contemporary drug-eluting stents (DES). In-stent restenosis was excluded. The DCB group included both patients undergoing DCB-only PCI and those receiving hybrid PCI with DCB and DES combined. The primary end point was target lesion failure at 2 years, defined as the composite of target lesion revascularization, cardiac death, and target vessel myocardial infarction. RESULTS: We included 147 consecutive patients undergoing DCB-based treatment on the left anterior descending artery and compared them to 701 patients who received conventional PCI with DES. In the DCB group, 43 patients (29.2%) were treated with DCB only and 104 (70.8%) with a hybrid approach; DCB length was greater than stent length in 55.1% of cases. Total treated length was higher in the DCB group (65 [40-82] versus 56 [46-66] mm; P=0.002), while longer DESs were implanted (38 [24-62] versus 56 [46-66] mm; P<0.001) and a higher rate of large vessels were treated (76.2% versus 83.5%; P=0.036) in the DES cohort. The cumulative 2-year target lesion failure incidence was not significantly different between the 2 groups (DCB, 4.1% versus DES, 9.8%; hazard ratio, 0.51 [95% CI, 0.20-1.27]; P=0.15). After a 1:1 propensity score matching resulting in 139 matched pairs, the DCB-based treatment was associated with a lower risk for target lesion failure at 2 years compared with DES-only PCI (hazard ratio, 0.2 [95% CI, 0.07-0.58]; P=0.003), mainly driven by less target lesion revascularization. CONCLUSIONS: A DCB-based treatment approach for left anterior descending revascularization allows a significantly reduced stent burden, thereby potentially limiting target lesion failure risk at midterm follow-up.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Stents Farmacológicos/efeitos adversos , Resultado do Tratamento , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Materiais Revestidos Biocompatíveis , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia
12.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668097

RESUMO

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
13.
Artigo em Inglês | MEDLINE | ID: mdl-37705369

RESUMO

BACKGROUND: De novo diffuse coronary artery disease (CAD) is a challenging scenario in interventional cardiology with limited treatment option, beside stent implantation. In this context, a hybrid approach, combining the use of drug-eluting stent (DES) and drug-coated balloon (DCB) to treat different segments of the same lesion (e.g. long lesion and/or true bifurcation), might be an interesting and alternative strategy to limit the metal amount. The aim of this study was to evaluate the safety and efficacy of a hybrid approach in addressing percutaneous treatment of de novo diffuse CAD. METHODS: This was a prospective, multicenter study including patients affected by de novo diffuse CAD treated with a hybrid approach from April 2019 to December 2020. Angiographic and clinical data were collected. The primary endpoint was the one-year device-oriented composite endpoint (DOCE, cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization [ID-TLR]). Periprocedural myocardial infarctions and periprocedural success were included among secondary endpoints. RESULTS: One hundred six patients were included, mean age was 68.2±10.2 years and 78.3% were male. De novo diffuse CAD consisted of 52.8% long lesions and 47.2% true bifurcation lesions. Significant increase in the final minimal lumen diameters and significant decrease in the final diameter stenosis were observed when compared to the baseline values in both DES- and DCB-target segments. Procedural success was 96.2%. DOCE at one-year was 3.7%, with all the adverse events characterized by ID-TLR. CONCLUSIONS: Combination of DES and DCB could be a safe and effective treatment option for the treatment of de novo diffuse CAD (NCT03939468).

14.
Am J Cardiol ; 207: 170-178, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37741107

RESUMO

There is a paucity of data regarding the safety of a 1-month dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) in patients at high bleeding risk (HBR) presenting with acute coronary syndromes (ACS). We aimed to compare the clinical outcomes of patients at HBR with chronic coronary syndrome (CCS) or ACS treated with PCI using bioresorbable polymer everolimus-eluting stent (BP-EES) followed by 1-month DAPT. Patients at HBR who underwent PCI with BP-EES were prospectively enrolled in 10 Italian centers. All patients were treated with 1-month DAPT. In case of need for anticoagulation, patients received an oral anticoagulant in addition to a P2Y12 inhibitor for 1 month, followed by oral anticoagulation only after that. The primary end point was a composite of cardiac death, myocardial infarction, or definite/probable stent thrombosis at 12 months. Overall, 263 patients (59.4%) with CCS and 180 patients (40.6%) with ACS were enrolled. No significant difference was evident between patients with CCS and ACS for the primary end point (4.3% vs 5.6%, respectively, p = 0.497) and for each isolated component. The risk for Bleeding Academic Research Consortium (BARC) type 1 to 5 or type 3 to 5 bleedings was also similar between patients with CCS and ACS (4.3% vs 5.2%, p = 0.677, and 1.6% vs 2.9%, p = 0.351, respectively). In conclusion, among HBR patients with ACS who underwent PCI with BP-EES, a 1-month DAPT strategy is associated with a similar risk of ischemic and bleeding events compared with those with CCS.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo/farmacologia , Inibidores da Agregação Plaquetária , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/tratamento farmacológico , Stents Farmacológicos/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos , Implantes Absorvíveis , Resultado do Tratamento , Hemorragia/induzido quimicamente , Anticoagulantes/uso terapêutico , Quimioterapia Combinada
15.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648345

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
17.
Eur Heart J Suppl ; 25(Suppl C): C79-C83, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125288

RESUMO

True coronary bifurcation lesions (CBL) represent a challenging scenario for percutaneous coronary interventions (PCI), and are associated with a higher risk of target lesion failure (TLF), particularly when two stents are implanted. A hybrid strategy combining a drug-eluting stent (DES) in the main branch, and a drug-coated balloon in the side branch may improve outcomes by reducing the total stent length while maintaining an effective anti-prolipherative action. In this sub-study of the HYPER trial, 50 patients with true CBL were treated with a hybrid strategy: procedural success was 96%, one case of peri-procedural myocardial infarction and one case of TLF (in a DES-treated segment) at 1 year were reported. This study suggests that such a hybrid strategy may be a safe and effective option for true CBL PCI, and warrants additional investigations to compare outcomes with standard of care strategies.

18.
G Ital Cardiol (Rome) ; 24(4 Suppl 2): 5S-15S, 2023 04.
Artigo em Italiano | MEDLINE | ID: mdl-37158025

RESUMO

In the last decades, advances in percutaneous coronary intervention (PCI) strategies have significantly reduced the risk of procedural complications and in-hospital mortality of patients with acute coronary syndromes (ACS), thus increasing the population of stable post-ACS patients. This novel epidemiological scenario emphasizes the importance of implementing secondary preventive and follow-up strategies. The follow-up of patients after ACS or elective PCI should be based on common pathways and on the close collaboration between hospital cardiologists and primary care physicians. However, the follow-up strategies of these patients are still poorly standardized. This SICI-GISE/SICOA consensus document was conceived as a proposal for the long-term management of post-ACS or post-PCI patients based on their individual residual risk of cardiovascular adverse events. We defined five patient risk classes and five follow-up strategies including medical visits and examinations according to a specific time schedule. We also provided a short guidance for the selection of the appropriate imaging technique for the assessment of left ventricular ejection fraction and of non-invasive anatomical or functional tests for the detection of obstructive coronary artery disease. Physical and pharmacological stress echocardiography was identified as the first-line imaging technique in most of cases, while cardiovascular magnetic resonance should be preferred when an accurate evaluation of left ventricular ejection fraction is needed. The standardization of the follow-up pathways of patients with a history of ACS or elective PCI, shared between hospital doctors and primary care physicians, could result in a more cost-effective use of resources and potentially improve patient's long-term outcome.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/diagnóstico , Volume Sistólico , Seguimentos , Consenso , Função Ventricular Esquerda , Resultado do Tratamento
19.
EuroIntervention ; 19(6): 512-525, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37235388

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) using dedicated devices is an alternative therapy for high-risk patients with symptomatic mitral regurgitation (MR). AIMS: This study aimed to assess the 2-year outcomes and predictors of mortality in patients undergoing TMVR from the multicentre CHOICE-MI Registry. METHODS: The CHOICE-MI Registry included consecutive patients with symptomatic MR treated with 11 different dedicated TMVR devices at 31 international centres. The investigated endpoints included mortality and heart failure hospitalisation rates, procedural complications, residual MR, and functional status. Multivariable Cox regression analysis was applied to identify independent predictors of 2-year mortality. RESULTS: A total of 400 patients, median age 76 years (interquartile range [IQR] 71, 81), 59.5% male, EuroSCORE II 6.2% (IQR 3.8, 12.0), underwent TMVR. Technical success was achieved in 95.2% of patients. MR reduction to ≤1+ was observed in 95.2% at discharge with durable results at 1 and 2 years. New York Heart Association Functional Class had improved significantly at 1 and 2 years. All-cause mortality was 9.2% at 30 days, 27.9% at 1 year and 38.1% at 2 years after TMVR. Chronic obstructive pulmonary disease, reduced glomerular filtration rate, and low serum albumin were independent predictors of 2-year mortality. Among the 30-day complications, left ventricular outflow tract obstruction, access site and bleeding complications showed the strongest impact on 2-year mortality. CONCLUSIONS: In this real-world registry of patients with symptomatic MR undergoing TMVR, treatment with TMVR was associated with a durable resolution of MR and significant functional improvement at 2 years. Two-year mortality was 38.1%. Optimised patient selection and improved access site management are mandatory to improve outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
20.
Circ Cardiovasc Interv ; 16(6): e013045, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194288

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. METHODS: The CHOICE-MI registry (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) included patients with MR undergoing TMVR using dedicated devices. Patients with MR pathogeneses other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation). We compared outcomes between the TMVR and GDMT groups, using propensity score matching to adjust for baseline differences. RESULTS: After propensity score matching, 97 patient pairs undergoing TMVR (72.9±8.7 years; 60.8% men; transapical access, 91.8%) versus GDMT (73.1±11.0 years; 59.8% men) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared with 6.9% and 7.7%, respectively, in those receiving GDMT alone (both P<0.001). The 2-year rate of heart failure hospitalization was significantly lower in the TMVR group (32.8% versus 54.4%; hazard ratio, 0.59 [95% CI, 0.35-0.99]; P=0.04). Among survivors, a higher proportion of patients were in the New York Heart Association functional class I or II in the TMVR group at 1 year (78.2% versus 59.7%; P=0.03) and at 2 years (77.8% versus 53.2%; P=0.09). Two-year mortality was similar in the 2 groups (TMVR versus GDMT, 36.8% versus 40.8%; hazard ratio, 1.01 [95% CI, 0.62-1.64]; P=0.98). CONCLUSIONS: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for heart failure, and similar mortality compared with GDMT. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04688190 (CHOICE-MI) and NCT01626079 (COAPT).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Pontuação de Propensão , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...